HydraulicsMediumMechMaxx MEC10

Auxiliary Hydraulic Line Installation - MechMaxx MEC10

Install or repair auxiliary hydraulic lines for attachments like breakers, augers, or thumbs.

Model Notes

MEC10 aux circuit is suitable for thumbs and light-duty attachments. Flow is limited by gear pump output.

Step-by-Step Guide for MechMaxx MEC10
1

Identify aux hydraulic ports on control valve.

2

Select appropriate hose sizes for attachment flow.

3

Route hoses along boom and arm, securing with clamps.

4

Install quick disconnect couplers at arm end.

5

Connect supply and return lines to valve ports.

6

Install aux control switch if not equipped.

7

Fill system and bleed air.

8

Test with attachment at low throttle first.

MechMaxx MEC10 Videos

No videos added for MechMaxx MEC10.

Add helpful YouTube tutorials specific to this model.

Required Components for MechMaxx MEC10

No specific components listed.